Symbols Glossary

Standard: EN ISO 15223-1:2021, Medical Devices – Symbols to be used with medical device labels, labelling and information to be supplied.
Symbol Reference Number of Symbol Title of Symbol Description of Symbol
5.1.1 Manufacturer Indicates the medical device manufacturer

 

5.1.3 Date of manufacture Indicates the date when the medical device was manufactured.

 

5.1.11 Country of manufacture To identify the country of manufacture of products

 

5.1.4 Use-by date Indicates the date after which the medical device is not to be used.

 

5.1.5 Lot number Indicates the manufacturer’s batch code so that the batch or lot can be identified.

 

5.1.6 Reference number Indicates the manufacturer’s catalogue number so that the medical device can be identified.

 

5.1.7 Serial number Indicates the manufacturer’s serial number so that a specific medical device can be identified.

5.1.8 Importer Indicates the entity importing the medical device into the locale.

5.1.9 Distributor Indicates the entity distributing the medical device into the locale.

 

5.2.1 Sterile Indicates a medical device that has been subjected to a sterilization process.

5.2.3 Sterilized using ethylene oxide Indicates a medical device that has been sterilized using ethylene oxide.
5.2.4 Sterilized using irradiation Indicates a medical device that has been sterilized using irradiation.

 

5.2.6 Do not resterilize Indicates a medical device that is not to be resterilized.

 

5.2.7 Non-sterile Indicates a medical device that has not been subjected to a sterilization process

 

5.2.8 Do not use if package is damage Indicates that a medical device that should not be used if the package has been damaged or opened and that the user should consult the instructions for use for additional information.

5.2.11 Single sterile barrier system Indicates a single sterile barrier system.
5.2.12 Double sterile barrier system Indicates two sterile barrier systems.

5.2.13 Single sterile barrier system with protective packaging inside Indicates a single sterile barrier system with protective packaging inside.

5.2.14 Single sterile barrier system with protective packaging outside Indicates a single sterile barrier system with protective packaging outside.
5.3.1 Fragile, handle with care Indicates a medical device that can be broken or damaged if not handled carefully.

5.3.2 Keep away from sunlight Indicates a medical device that needs protection from light sources.

 

5.3.4 Keep dry Indicates a medical device that needs to be protected from moisture.

5.3.7 Temperature limit Indicates the temperature limits to which the medical device can be safely exposed.

 

5.4.2 Do not re-use Indicates a medical device that is intended for one single use only.
5.4.3 Consult instructions for use or consult electronic instructions for.

use.

Indicates need for the user to consult the instructions for use.

 

5.4.3 Consult Instructions For Use.

Available on the Surgalign website www.surgalign-wpe.adkalpha.com/eIFU/

Indicates need for the user to consult the instructions for use.

 

5.4.4 Caution Indicates that caution is necessary when operating the device or control close to where the symbol is placed, or that the current situation needs operator awareness or operator action in order to avoid undesirable consequences.

5.7.2 Indicates the name of the patient When used, the symbol shall appear adjacent to the patient name or next to a space provided to record it.

5.7.3 Patient identification Indicates the identification data of the patient.

 

 

5.7.4 Patient information website Indicates a website where a patient can obtain additional information on the medical product.

5.7.5 Health care centre or doctor Indicates the address of the health care centre or doctor where medical information about the patient may be found.

5.7.6 Date Indicates the date that information was entered or a medical procedure took place

5.7.7 Medical device Indicates the item is a medical device.

5.7.10 Unique device identification Indicates a carrier that contains unique device identifier information.

 

 

Symbol Standard/Symbol Reference Number Title of Symbol Description of Symbol

 

21 CFR 801.109 Prescription only Requires prescription in the United States.
21 CFR 801.109 Caution: Federal law restricts this device to sale by or on the order of a physician N/A

 

Regulation (EU) 2017/745 Annex V  

CE Mark for Class I devices

N/A

 

Regulation (EU) 2017/745 Annex V

 

CE Mark for Class Is, Im, Ir, IIa, IIb, III  devices

 

N/A

 

ASTM F2503 MR Conditional Medical device that has been demonstrated to pose no known hazards in a specified MR environment with specified conditions of use.

EN 50419 – Marking of electrical equipment in accordance with Article 11 (2) of Directive 2002/96/EC

4.1 b) 2)

Electronic Equipment: Dispose of Properly Indicates electronic equipment to be disposed of properly.

IEC TR 60878:2015 – Graphical symbols for electrical equipment in medical practice

5017

Protective earth To identify an earth (ground) terminal

ISO 7010:2011 Graphical symbols – Safety colours and safety symbols – Registered safety signs

P017

No pushing To prohibit pushing against an object

ISO 7010:2011 Graphical symbols – Safety colours and safety symbols – Registered safety signs

M002

Follow instructions for use To signify that the instruction for use must be read